Basic Info.

Model NO.
WW05-22VM/VT(R290)
Heating Capacity
4kw-16kw
Unit Type
Inverter
Application Scope
Hotels, Clubs, Hospitals, Villas and etc
Transport Package
Factory Standard
Specification
1050*410*950mm
Trademark
Wotech
Origin
China
HS Code
84186120

Product Description

R290 Air Source water heater Replace Gas Fuel Heater with CE/CB Certificate
 
Features

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Features:

1.Hot water up to 75C,suitable for underfloor/radiator heating/fan coil

2.can work stable at ambient temperature -25C to 45C

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R290 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

Installation Diagram

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Installation Diagram:
 
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Two Heating circuits

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Two heating circuits


More flexibility thanks to two zones control

Independent temperature control of underfloor heating and radiator heating

User interface shows two different zones temperature

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Technical Parameter


R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Technical Parameter:
Market model   WW07VM WW09VM WW12VM WW15VM WW20VT WW22VT
Heating1
A7 W35
Output Capacity kW 2.84~7.20 3.61~9.17 4.75~12.06 5.83~14.80 8.03~20.38 8.71~22.12
Input Power  kW 0.51~1.58 0.67~2.07 0.87~2.67 1.09~3.36 1.50~4.62 1.66~5.09
COP - 4.56~5.52 4.43~5.36 4.51~5.46 4.40~5.32 4.41~5.34 4.35~5.26
Input Current A 2.35~7.23 3.08~9.47 3.98~12.24 5.01~15.39 2.69~8.27 2.96~9.10
Heating2
A7 W55
Output Capacity kW 2.60~6.83 3.27~8.60 4.51~11.88 5.41~14.24 7.49~19.72 8.29~21.82
Input Power  kW 0.72~2.24 0.94~2.91 1.26~3.92 1.57~4.88 2.08~6.44 2.41~7.47
COP - 3.05~3.60 2.96~3.49 3.03~3.58 2.92~3.45 3.06~3.61 2.92~3.45
Input Current A 3.30~10.25 4.28~13.30 5.78~17.94 7.19~22.32 3.71~11.53 4.30~13.37
Heating3
A20 W55
Output Capacity kW 3.54~8.86 4.47~11.19 5.98~14.95 7.16~17.91 10.03~25.07 10.71~26.77
Input Power  kW 0.69~2.01 0.88~2.57 1.15~3.38 1.40~4.11 1.96~5.72 2.13~6.24
COP - 4.41~5.16 4.36~5.10 4.43~5.18 4.36~5.10 4.38~5.12 4.29~5.02
Input Current A 3.14~9.19 4.01~11.74 5.28~15.45 6.43~18.80 3.50~10.24 3.82~11.16
Cooling4
A35 W7
Output Capacity kW 2.11~5.02 2.95~7.03 3.83~9.12 4.45~10.59 5.90~14.05 6.38~15.20
Input Power  kW 0.67~1.89 0.98~2.76 1.30~3.65 1.58~4.45 1.98~5.58 2.24~6.31
EER - 2.65~3.13 2.55~3.01 2.50~2.95 2.38~2.81 2.52~2.97 2.41~2.84
Input Current A 3.09~8.67 4.49~12.62 5.94~16.70 7.25~20.36 3.55~9.97 4.02~11.28
Power Supply  V/PH/HZ 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 380-415V/3/50Hz 380-415V/3/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++ A++ A++
Water Side Heat Exchanger   - Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger
Display controller  - LCD touch screen LCD touch screen LCD touch screen LCD touch screen LCD touch screen LCD touch screen
Backup heater (Optional)  kW 3kW  3kW  3kW  3kW  3kW  3kW 
Expansion vessel / 3L 3L 5L 5L 5L 5L
Refrigerant Type  - R290 R290 R290 R290 R290 R290
Max Oulet Water Temperature ºC 75 75 75 75 75 75
Working Ambeint Temperature ºC -25~43 -25~43 -25~43 -25~43 -25~43 -25~43
Water connection  inch G1-1/4 G1-1/4 G1-1/4 G1-1/4 G1-1/4 G1-1/4
Sound pressure Level @1m  dB(A) 50 50 52 53 58 58
Net Dimension (L*W*H)  mm 1085*440*840 1085*440*840 1150*430*960 1150*430*960 1150*430*1400  1150*430*1400 
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC. 
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
 
Key Functions:

 

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

R32 environmental refrigerant

1. R32 has a GWP of 675, roughly 30% lower than that of R410A
2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate
3. Ozone Depletion Potential of 0
4. Easier to recycle than R410A, as R32 is a single component refrigerant
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

DHW tank disinfection

The DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate


Climate curve
You can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

Floor preheating and drying

Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

Powerful heating with high efficiency

1. No capacity attenuation at -l0°C ambient temperature
2. Operation range down to -25°C
3. Maximum LWT reach 60°C 
4. Energy efficiency level: A+++
 
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

 

Mode combination

There are 4 single operation mode (Cool,Heat,DHW,Auto) and 3 combined operation mode to meet different demands of using.
 
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
 

Fast DHW

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
 
Project cases

 

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Wotech Project cases:
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
 
Manufacturing & Laboratories

 

R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate
Manufacturing & Laboratories
R290 Air Source Water Heater Replace Gas Fuel Heater with CE/CB Certificate

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours