Basic Info.
Model NO.
WW08-22VM/VT(R32 Monoblock)
Heating Capacity
8kw-16kw
Unit Type
Inverter
Application Scope
Hotels,Clubs,Hospitals,Villas and etc
Transport Package
Factory Standard
Specification
995*410*800mm
Trademark
Wotech
Origin
China
HS Code
84186120
Product Description
R32 Air to Water Air Source water heater Replace Gas Fuel Heater CE/CB Certificate
Installation Diagram:
Two heating circuits
○ More flexibility thanks to two zones control
○ Independent temperature control of underfloor heating and radiator heating
○ User interface shows two different zones temperature
Technical Parameter:
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
Climate curve
You can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
Wotech Project cases:
Manufacturing & Laboratories
Features:
1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil
2.can work stable at ambient temperature -25ºC to 45ºC
3.E-Heater,diverter valve and water pump can be inclueded
4. A+++ Energy Rating Level
5.Full inverter system,Stable and efficient performance.
6.R32 System,environment friendly
7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water
8.With Wifi App control
1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil
2.can work stable at ambient temperature -25ºC to 45ºC
3.E-Heater,diverter valve and water pump can be inclueded
4. A+++ Energy Rating Level
5.Full inverter system,Stable and efficient performance.
6.R32 System,environment friendly
7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water
8.With Wifi App control
Installation Diagram:
Two heating circuits
○ More flexibility thanks to two zones control
○ Independent temperature control of underfloor heating and radiator heating
○ User interface shows two different zones temperature
Monoblock Series Application Diagram
Technical Parameter:
Market model | WW08V | WW10V | WW12V | WW14VM | ||
Heating1 | Output Capacity | kW | 3.40~8.65 | 3.70~10.30 | 4.95~12.46 | 5.92~14.94 |
Input Power | kW | 0.59~1.65 | 0.62~2.05 | 0.90~2.48 | 1.15~3.20 | |
COP | - | 5.23~5.72 | 5.02~5.90 | 5.03~5.50 | 4.67~5.12 | |
Input Current | A | 2.82~7.92 | 2.96~9.81 | 4.31~11.85 | 5.50~15.3 | |
Heating2 | Output Capacity | kW | 3.43~7.77 | 3.90~9.84 | 4.37~12.43 | 5.18~14.30 |
Input Power | kW | 0.91~2.41 | 1.01~3.12 | 1.21~3.95 | 1.33~4.69 | |
COP | - | 3.23~3.80 | 3.15~3.81 | 3.15~3.61 | 3.05~3.89 | |
Input Current | A | 2.56~11.52 | 4.83~14.93 | 5.78~18.89 | 6.36~22.45 | |
Heating3 | Output Capacity | kW | 4.11~10.37 | 5.10~13.25 | 6.25~14.63 | 7.52~16.57 |
Input Power | kW | 0.74~2.28 | 0.94~13.73 | 1.14~3.12 | 1.37~3.56 | |
COP | - | 4.55~5.56 | 4.61~5.42 | 4.69~5.46 | 4.66~5.47 | |
Input Current | A | 3.54~10.91 | 4.50~12.49 | 5.45~14.93 | 6.55~17.03 | |
Cooling4 | Output Capacity | kW | 3.04~7.57 | 3.82~8.21 | 5.05~11.45 | 6.02~12.31 |
Input Power | kW | 0.94~2.75 | 1.18~3.02 | 1.54~4.13 | 1.87~4.53 | |
EER | - | 2.75~3.23 | 2.72~3.25 | 2.77~3.28 | 2.73~3.22 | |
Input Current | A | 4.50~13.15 | 5.64~14.45 | 7.37~19.76 | 8.95~21.67 | |
Power Supply | V/PH/HZ | 220-240V/1/50Hz | ||||
ErP level(35ºC) | - | A+++ | A+++ | A+++ | A+++ | |
ErP level(55ºC) | - | A++ | A++ | A++ | A++ | |
Water Side Heat Exchanger | - | Plate heat exchanger | ||||
Display controller | - | LCD touch screen | ||||
Backup heater (Optional) | kW | 3kW | ||||
Expansion vessel | / | 5L | ||||
Refrigerant Type | - | R32 | ||||
Max Water Temperature (without backup heater) | ºC | 60 | ||||
Working Ambeint Temperature | ºC | -25~43 | ||||
Water connection | inch | G1-1/4 | ||||
Sound pressure Level @1m | dB(A) | 50 | 50 | 52 | 53 | |
Net Dimension (L*W*H) | mm | 995*410*800 | 995*410*800 | 1065*410*960 | 1065*410*960 |
Market model | WW14VT | WW16V | WW18V | WW20V | WW22V | ||
Heating1 | Output Capacity | kW | 5.92~14.94 | 6.48~16.38 | 7.29~18.51 | 8.10~20.56 | 8.91~22.35 |
Input Power | kW | 1.15~3.20 | 1.29~3.58 | 1.39~3.98 | 1.56~4.49 | 1.73~5.06 | |
COP | - | 4.67~5.12 | 4.57~5.01 | 4.65~5.25 | 4.58~5.20 | 4.42~5.13 | |
Input Current | A | 2.05~5.71 | 2.31~6.41 | 2.49~7.12 | 2.79~8.03 | 3.09~9.06 | |
Heating2 | Output Capacity | kW | 5.18~14.30 | 5.93~16.58 | 6.67~18.65 | 7.41~20.68 | 8.15~21.15 |
Input Power | kW | 1.33~4.69 | 1.39~5.63 | 1.58~6.43 | 1.77~7.18 | 1.97~7.50 | |
COP | - | 3.05~3.89 | 2.94~4.26 | 2.90~4.22 | 2.88~4.18 | 2.82~4.13 | |
Input Current | A | 2.38~8.39 | 2.48~10.07 | 2.83~11.50 | 3.17~12.84 | 3.52~13.42 | |
Heating3 | Output Capacity | kW | 7.52~16.57 | 8.95~19.42 | 10.07~21.85 | 11.18~24.05 | 12.30~25.5 |
Input Power | kW | 1.37~3.56 | 1.62~4.21 | 1.84~4.77 | 2.08~5.31 | 2.33~5.73 | |
COP | - | 4.66~5.47 | 4.61~5.52 | 4.58~5.46 | 4.53~5.38 | 4.45~5.28 | |
Input Current | A | 2.45~6.37 | 2.90~7.53 | 3.29~8.53 | 3.72~9.50 | 4.17~10.25 | |
Cooling4 | Output Capacity | kW | 6.02~12.31 | 7.23~14.82 | 8.13~15.72 | 9.03~16.67 | 9.93~17.50 |
Input Power | kW | 1.87~4.53 | 2.27~5.43 | 2.64~5.86 | 3.00~6.36 | 3.35~6.78 | |
EER | - | 2.73~3.22 | 2.73~3.18 | 2.68~3.08 | 2.62~3.01 | 2.58~2.96 | |
Input Current | A | 3.34~8.10 | 4.06~9.71 | 4.72~10.48 | 5.37~11.38 | 6.00~12.13 | |
Power Supply | V/PH/HZ | 380-415V/3/50Hz | |||||
ErP level(35ºC) | - | A+++ | A+++ | A+++ | A+++ | A+++ | |
ErP level(55ºC) | - | A++ | A++ | A++ | A++ | A++ | |
Water Side Heat Exchanger | - | Plate heat exchanger | |||||
Display controller | - | LCD touch screen | |||||
Backup heater (Optional) | kW | 3kW | |||||
Expansion vessel | / | 5L | |||||
Refrigerant Type | - | R32 | |||||
Max Water Temperature (without backup heater) | ºC | 60 | |||||
Working Ambeint Temperature | ºC | -25~43 | |||||
Water connection | inch | G1-1/4 | |||||
Sound pressure Level @1m | dB(A) | 53 | 56 | 56 | 58 | 58 | |
Net Dimension (L*W*H) | mm | 1065*410*960 | 1065*410*960 | 1150*430*1350 | 1150*430*1350 | 1150*430*1350 |
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
R32 environmental refrigerant
1. R32 has a GWP of 675, roughly 30% lower than that of R410A
2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate
3. Ozone Depletion Potential of 0
4. Easier to recycle than R410A, as R32 is a single component refrigerant
DHW tank disinfection
The DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.
Climate curve
You can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
Floor preheating and drying
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.Powerful heating with high efficiency
1. No capacity attenuation at -l0°C ambient temperature
2. Operation range down to -25°C
3. Maximum LWT reach 60°C
4. Energy efficiency level: A+++
Mode combination
There are 4 single operation mode (Cool,Heat,DHW,Auto) and 3 combined operation mode to meet different demands of using.
Fast DHW
You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
Wotech Project cases:
Manufacturing & Laboratories